WARNING AND ERROR MESSAGE
It incorporates a variety of functions for the systems to verify processes and the state of the
electronics. In case of an error the screen will display the cause of error and emit an
audible sound.
Incorrect polarity connected.
The battery is interrupted.
CONNECT error
Check Main Port
The Battery connection is wrong.
The cell number is wrong.
CELL number
Incorrect
Voltage of one cell in the battery pack is too high.
CELL error
High Voltage
Voltage of one cell in the battery pack is too low.
CELL error
Low Voltage
The internal temperature of the unit goes too high.
Int.temp.too hi
DC in too low
Input voltage less than 11V.
Input voltage higher than 18V.
DC in too high
BATTERY WAS FULL
The battery voltage is higher than the maximum voltage
which the user sets when charging in balance mode.
CELL error
Voltage-Invalid
Voltage of one cell in the battery pack is invalid.
The external temperature of the unit goes too high.
Ext.temp.too hi
Over charge
Capacity Limit
The battery capacity is more than the maximum capacity
which the user sets.
Over TIME LIMIT
The charging time is longer than the maximum charging
time which the user sets.
BALANCE CONNECT
ERROR
The balance connect is wrong.